No. | Item | Time(M) | Temperature | Remark |
1 | Pre-wash | 10 | Room temp.or 50°C | Tap Water or pure water |
2 | Alkali solution | 10-30 | 60-80°C | 2-4% NaOH solution |
3 | Hot water | 10-20 | 60-80°C | Tap water or pure water |
4 | Acid solution | 10-30 | 60-80°C | 2% HNO3 solution |
5 | Final wash | 15 | 60-80°C | Pure water |
NO | Name | Buyer | Seller |
1 | CIP SYSTEM | √ | |
2 | CONTROL PANEL | √ | |
3 | EQUIPMENTS INSTALLATION | √ | |
4 | EQUIPMENT PIPELINE CONNECTION | √ | |
5 | EQUIPMENT COMMISSION | √ | √ |